1. Technical advantages
Coating uniformity: edge coverage > 20μm, film thickness
deviation ≤ ±1.5μm
Environmentally friendly and efficient: coating utilization >
98%, VOC emissions close to zero
Anti-corrosion performance: CASS test > 120h, neutral salt spray
> 1000h without rust
Intelligent: tank liquid life > 12 months (with EDI regeneration
system), support IoT remote monitoring
2. Selection and use points
Industry adaptation: Automotive industry: fully enclosed tank +
automatic conveying system for driving
Hardware: choose compact tank (minimum capacity 5m³) + Manual
hanger
Supporting requirements: Pure water system: water resistivity ≥
15MΩ·cm (RO+EDI device required)
Power configuration: Three-phase 380V±10%, independent grounding
system recommended
Maintenance recommendations: Check tank parameters (solid
content/ash content/MEQ value) monthly
Replace ultrafiltration membrane every six months, and acid wash
and regenerate anode plates every year
Note: It is recommended to add an online membrane thickness
detector (±1μm accuracy) and a tank automatic balance system (to
reduce manual intervention)
1. Core structure
1. Main tank system
Material: 316L stainless steel or PP lining (acid and alkali
resistant, electrochemical corrosion resistant)
Capacity: customized according to workpiece size (typical capacity
10-50m³), including overflow weir design (liquid level fluctuation
≤±2mm)
Insulation design: The insulation resistance between the tank and
the ground is ≥10MΩ to prevent leakage risk
2. Circulation filtration system
Main circulation pump: magnetic drive non-leakage pump (flow rate
50-300m³/h, head 15-30m)
Filter unit: two-stage bag filter (precision 20μm) +
ultrafiltration membrane system (molecular weight cutoff 5000Da)
Temperature control module: titanium tube heat exchanger
(temperature control accuracy ±1℃) + Cooling tower linkage
3. Electrode system
Cathode: Workpiece hanger (DC voltage 100-400V adjustable, current
density 1-3A/dm²)
Anode: 316L stainless steel plate or titanium-based mixed metal
oxide (MMO) coating
Gap adjustment: Servo motor drive, dynamic adjustment of plate
spacing (accuracy ±3mm)
II. Key parameter indicators
Module | Technical specifications | Control standard |
Working voltage | DC 150-350V (adjustable in sections) | Constant pressure/constant current dual mode |
Temperature of bath | 28-32℃ (automatically cuts off power when over-temperature) | PID intelligent temperature control |
Conductivity | 1200-1600μS/cm | Online monitoring + automatic addition |
Solid content | 18-22% (ultrafiltration system maintenance) | Determination by rotary evaporation method |
3. Core functional components
Rectifier power supply: high-frequency inverter (ripple factor <3%, conversion efficiency ≥95%)
UF ultrafiltration system: membrane pore size 0.02μm, permeate recovery rate >95%
Post-flushing unit: four-stage countercurrent spray (RO water + UF liquid recovery)
Tanking liquid management: pH/conductivity/temperature three-parameter interlocking control + automatic feeding system
1.High cost performance: Based on the customer's product
positioning and development strategy, and with economic
affordability as the foundation, we achieve the best cost
performance.
2.The advanced and meticulous design concept of the equipment,
along with the highly automated industrial equipment, showcases the
image of a modern and advanced enterprise.
3. It has high adaptability, meeting the current production
requirements and reserving room for development, taking into
account the needs of increased production and improved quality in
the future.
4.Quality compliance strictly adheres to the ISO900 quality
management system, with every minute detail of the entire equipment
installation being strictly controlled.
![]() |